User Manual Dimplex OMWFC20 REDWAY Wall Mounted Electric Fire Heater

Documents for Dimplex REDWAY

The following documents are available:
User Manual Other Documents
  • REDWAY - Dimplex - Specifications Sheet - (English) Download
Photos
REDWAY photo
2. View the lamps from a distance in front of the re and observe which lamp needs to be changed.
3. Press switch A to o (0) position (See Fig.2), and unplug the re from the mains.
4. Leave the appliance for 20 minutes to allow the lamps to cool down before removing them.
5. Remove the water tank by lifting upwards and place in a sink.
6. Remove the sump as described in the Cleaning Section.
7. Remove the defective lamp, by gently lifting vertically and disengaging the pins from the lamp holder, (See Fig.4 and 4a).
Replace with a Dimplex Opti-myst, 12V, 45W, Gu5.3 base, 8º beam angle, coloured lamp. (To purchase replacement lamps go
to the section After Sales Service’, details of how to purchace the lamps are contained therein.)
8. Carefully insert the two pins of the new lamp into the two holes in the lamp holder. Push lamp rmly in place. (See Fig.4 and
4a).
9. Replace the nozzle, water tank and fuelbed.
10. Switch on.
Filling the water tank.
When the water tank is empty, the ame and smoke eect shuts o and you will hear 2 audible ‘beeps,, follow these steps.
1. Press Switch A to o position (0) (See Fig.2)
2. Gently lift out the fuelbed and place carefully on the ground. (See Fig.3)
3. Remove the water tank by lifting upwards and outwards.
4. Place the water tank in sink and remove cap, Anti-clockwise to open. (See Fig.5)
5. Fill tank with ltered tap water only. This is necessary to prolong the life of the ame and smoke producing unit.
The water should be ltered through a conventional domestic water lter unit and the lter should be replaced regularly.
6. Screw the cap back on, do not overtighten.
7. Return the tank to the sump, with the tank cap facing down and the at side of the tank facing outward.
8. Gently place the fuelbed back into position.
9. Press Switch A to ‘ON ( I ) position (See Fig.2)
Cleaning.
WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER.
We Recommend cleaning the following components once every 2 weeks, particularly in hard water areas:-
Water Tank, Sump, Nozzle, Tank cap and seal, Air lter.
For general cleaning use a soft clean duster – never use abrasive cleaners. To remove any accumulation of dust or u the soft
brush attachment of a vacuum cleaner should occasionally be used to clean the outlet grille of the fan heater.
Water tank
1. Remove water tank, as described earlier, put into sink and empty water.
2. Using the supplied brush gently rub the inside surfaces of the cap paying particular attention to the rubber ring in the outer
groove and the centre rubber seal.
3. Put a small quantity of washing up liquid and water into the tank, ret the cap and shake well, rinse out until all traces of
washing up liquid are gone.
4. Rell with ltered tap water only, replace the cap, do not overtighten.
Sump
1. Press Switch A to the ‘OFF’ (0) position
2. Gently lift out the fuelbed and place carefully on the ground. (See Fig.3)
3. Remove the water tank by lifting upwards.
4. Disconnect the electrical connector, located on the right side of the sump. (See Fig.6) .
5. Release the right sump locking tabs by turning 90º, this allows the sump to be lifted completely from its location. (See Fig.6a)
6. Gently lift up the sump, taking care to keep level so as not to spill any water. Sit the assembly in the sink.
7. Release the left sump locking tabs by turning 90º, then lift o the Nozzle. (See Fig.4)
8. Remove the transducer and carefully tilt the sump as shown, so that the liquid drains out of the sump. (See Fig.8)
9. Put a small amount of washing up liquid into the sump, and using the supplied brush, gently clean all surfaces in the sump
and gently clean the transducer including the metal discs located in the top grooved surface. (See Fig.9)
10. When cleaned, thoroughly rinse the sump and transducer with clean water.
11. Clean the smoke outlet surface of the sump lid with the brush and ush out thoroughly with water. (See Fig.10)
12. Reverse the above steps to reassemble.
Air lter.
1. Press Switch A to the ‘OFF’ (0) position (See Fig.2)
2. Gently lift out the fuelbed and place carefully on the ground. (See Fig.3)
3. Gently slide upwards the air lter out of its plastic holder. (See Fig.11)
4. Gently rinse with water in the sink and dry with fabric towel before returning.
5. Replace the lter making sure that the course black lter is facing the front of the re.
6. Replace the fuelbed.
7. Press Switch A to the ‘ON ( I ) position (See Fig.2)

Specifications