Loading ...
Loading ...
Loading ...
7. After draining the water,replace and tighten drain cap.
8. Dry the interior and exterior with a clean,soft cloth.
NOTE: It is strongly recommended to clean the unit before initial use or after the
unit has not been in use for a long period of time.
Circuit Diagram
Common malfunction analysis
1) NO ICE
Issues
Check items
Possible causes
solutions
The
machine
doesn’t
work
Power cord
The plug didn’t
plug into socket
Plug into socket
The fuse of
PCB
The fuse is
melted or
broken
Replace the fuse
Ice bin
The ice is full
Clean out the ice cubes
Power supply
No power or
lower voltage
Contact power supply bureau
Water supply
No water or
water pressure
is low
Check water source and its pressure
Inlet valve
Inlet valve is
broken
Replace the inlet valve
Proximity
switch
Proximity switch
is broken
Replace the proximity switch
Compress
Power supply
Lower voltage
Contact power supply bureau
Loading ...